System Components Installation and Connection
37
1. Connect one wire to TB3 pin1 (External PTT) and the other to TB3 pin 3
(Ground).
2. Cut the trace across position A of JP8 and solder a wire in position B. This
ensures that the front panel mic is enabled when this input goes active.
External Amplified Speaker
Connect the speaker audio input to TB3 pin 9 (External Speaker) and its ground lead to
TB3 pin 8 (Ground).
Recorder
To connect the recorder:
1. Connect the recorder audio input to TB3 pin 10 (Recorder Audio).
2. Connect its ground lead to TB3 pin 8.
3. Use the output from TB3 pin 11 (Recorder Enable) to enable the recording
device. It pulls to ground whenever a signal is present.
Supervisor Takeover
Use TB3 pin 12 to activate an external relay to disconnect downstream remotes.
When the remote initiates privacy mode, this output is pulled to ground.
Wall Mounted Remote
Remotes can sit on a desk or be mounted on a wall.
To wall-mount a remote:
1. Remove the back cover, rotate it 180°, and reattach it.
2. Pull out the clear plastic insert under the handset and remove the screw
underneath.
3. Flip the handset hanger over, and replace the screw and the plastic insert.
4. Use the holes on the back cover to mount the remote.